🩺 Quick diagnosis: find your problem
Match what you're seeing to the most likely cause, then jump to the section for the full fix.
| Symptom | Likely cause | Quick fix | Details |
|---|---|---|---|
| Capsule won't come out | Resin on chamber or capsule, overfilling, lid-side down | Let it cool, flip the device, tap; clean the chamber cold | Stuck capsule |
| Lid won't open, or bends | Residue on the rim, thin aluminum lid | Open cool, work around the edge, don't force it | Lids |
| Bottom is pushed in | Pressure while filling or removing | Use it a few more times at most, then retire it | Dents |
| Draw feels tight | Capsules reduce airflow, dense fill | Open the Venty airflow wheel, fill looser | Tight draw |
| Top browned, bottom green | Temperature too low, packed too firm | Raise temp a little, stir, finish with Superbooster | Uneven extraction |
| Flavor dull, lids sticky | Resin buildup | Isopropyl soak, rinse, dry fully | Resin |
| Herb loose in your bag | Lids knocked off in transit | A Magazine, Capsule Caddy or small sealed case | Storage |
ℹ️ Getting multiple uses out of a capsule
Most of the problems below come from resin and wear building up as a capsule is used again and again. A few habits prevent almost all of them: open and empty capsules after each session, don't overfill, and swap in a fresh one when a capsule gets sticky, dented, or its lid no longer seats. Ours last at least a dozen uses before they need cleaning.
The capsules we sell are made for multiple uses. They're our own capsules, not made by Storz & Bickel, and fit the Mighty, Crafty and Venty with no adapter.
🔒 Capsule stuck in the chamber
Symptom. You tip the device over and the capsule stays put.
Likely cause. Three things cause almost every stuck capsule: resin on the chamber walls or on the outside of the capsule, a capsule that was overfilled so the lid bulges, or a capsule inserted lid-side down.
Fix.
Switch off and let it cool
Give the device a few minutes to cool before you touch the capsule.
Turn it upside down and tap
Hold the device chamber-down over a towel or a hard surface and tap it gently against your palm. Most capsules drop out here.
Don't pry with metal
Knives and metal picks scratch the chamber. The Mighty+ and the updated Crafty+ have a ceramic-coated chamber, and it's worth keeping it that way.
Clean the chamber cold
Clean the chamber with a swab dipped in 91% isopropyl, with the device held upside down so nothing runs down inside. Only do this with the device off and cold, and let it dry fully before heating.
Clean the capsule too
If the outside of the capsule is sticky, swap in a fresh one, or soak it in isopropyl, then rinse and dry it fully before it goes back in.
Prevention. Always insert the capsule lid-side up (Storz & Bickel says the same). Fill level with the rim, not above it, so the lid sits flat. Keep the chamber clean: a thin film of resin is enough to grip a capsule. The Mighty troubleshooting guide covers other chamber issues.
🫙 Lids hard to open or bent
Symptom. The lid won't budge, or it bends out of shape when you pull on it.
Likely cause. Residue building up around the rim is the usual culprit. Aluminum lids are also thin and bend easily, which is hard on stiff or sore fingers.
Fix. Let the capsule cool fully first. Work the lid loose gradually around the edge with a fingernail or a plastic pick instead of pulling from one spot. If residue has glued it shut, a short isopropyl soak softens it. If a bent lid won't sit snugly after you press it flat, it won't hold the herb in.
Prevention. Empty capsules after each session rather than leaving spent herb inside, and swap in a fresh capsule once it gets sticky. Don't overfill: a lid pressed onto a heaped capsule bends at the edge. Retire any capsule whose lid no longer seats.
🔨 Dented bottoms
Symptom. The base of the capsule is pushed in or warped.
Likely cause. Thin aluminum deforms under pressure: pressing too hard while filling, pushing a capsule out from below, or rattling around loose in a bag. Deformed bottoms after first use are common.
Fix. Some owners report using dented capsules a few more times without trouble. But a dented capsule sits less evenly and sticks more easily, so treat a dent as the start of its retirement.
Prevention. Tamp lightly, not hard. Tip capsules out rather than pushing them. Carry them in a case, not loose.
💨 Tight draw, especially on the Venty
Symptom. You have to pull hard, and vapor feels thin, more so with a capsule than with loose herb.
Likely cause. Storz & Bickel notes that dosing capsules may reduce airflow. A densely packed capsule makes it worse.
Fix. On the Venty, open the airflow wheel (it goes up to 20 L/min). Refill the capsule less densely: level with the rim and pressed lightly, not packed hard.
Prevention. Use a medium, even grind and a light press. More on filling in how to use dosing capsules and on the Venty specifically in Venty dosing capsules.
🌗 Uneven extraction
Symptom. You empty the capsule and part of it is browned while the rest still looks green.
Likely cause. The temperature is a little low for a capsule, or the herb is packed so firmly that heat doesn't reach the middle.
Fix. Try any of these:
- Raise the temperature a little and see if the next capsule browns more evenly. Our temperature guide helps you pick a starting point.
- Stir and lightly tamp halfway through. Let it cool, open, stir, press lightly and close.
- Finish with the Superbooster. On the Mighty+ and Crafty+, a triple click on the power button triggers it for the last few draws, and it reverts to your base temperature after 90 seconds.
Prevention. Even grind, light press, and don't overfill.
🔥 Handling hot capsules
A capsule straight out of the chamber is hot. Don't pick it up with bare fingers. Tip it out onto a hard, heat-safe surface and give it about 30 seconds to cool before you handle it or open the lid.
🧼 Resin buildup and cleaning
Symptom. Flavor gets duller, lids stick, and the capsule feels tacky.
Likely cause. Every session leaves a little residue, and it builds up with reuse.
What to do. Our capsules last at least a dozen uses before they need cleaning. After that you can soak them in isopropyl, rinse them and let them dry fully before refilling, but at 50 ₪ for 40 it's usually simpler to swap in fresh ones.
Device cleaning routines are in how to clean the Mighty, how to clean the Crafty and how to clean the Venty.
🎒 Lids popping off in a bag
Symptom. You reach for a filled capsule and find herb loose in your bag.
Likely cause. Loose capsules get squeezed and knocked around, and a lid that's slightly bent pops off easily.
Fix and prevention. Keep filled capsules in a holder. Storz & Bickel sells the Magazine, which holds 8 capsules, and a Capsule Caddy. A small sealed case works too. Retire capsules whose lids have loosened, since they're the ones that open in transit. See Storz & Bickel accessories for more.
Fresh capsules when yours are bent
40 food-grade aluminum dosing capsules for the Mighty, Crafty and Venty, no adapter needed. Our own capsules, made for multiple uses. 50 ₪ for 40 (was 80 ₪). We ship worldwide, with 30-day returns.
Shop the 40-pack →♻️ When to retire a capsule
Replacing a worn capsule is often the real fix. Retire a capsule when:
- the bottom or walls are dented or warped;
- the lid no longer seats snugly, or pops off on its own;
- the lid is bent, creased or torn;
- residue won't come off after a soak;
- it keeps sticking in a clean chamber.
While you're at it, check the 15 mm screen in your cooling unit. A clogged or bent screen also causes weak vapor and a tight draw. We sell them for 2 ₪ each or 8 ₪ for 5.